other

SFP+ 16G C17-C61 DWDM 20KM DDM Optical Transceiver


Product Features


  • Supports up to 14.025Gbps bit rates
  • Hot-pluggable SFP+ footprint
  • 100GHz ITU, C Band DWDM Cooled EML laser and PIN photodiode, Up to 20km for SMF transmission
  • Compliant with SFP+ MSA and SFF-8472 with duplex LC receptacle
  • Compatible with RoHS
  • Single +3.3V power supply
  • Real Time Digital Diagnostic Monitoring
  • Operating case temperature:
  • Standard:  0 to +70°C


Applications


  • 4.25/8.5/14.025G Fibre channel
  • Other Optical links





  • 产品详细信息


RSPD-16GD20-CXX
14.025Gbps SFP+ DWDM Transceiver, Single Mode, 20km Reach




Description


  • The SFP+ transceivers are high performance, cost effective modules supporting data rate of 14.025Gbps and 20km transmission distance with SMF.
  • The transceiver consists of three sections: a Cooled EML laser transmitter, a PIN photodiode integrated with a trans-impedance preamplifier (TIA) and MCU control unit. All modules satisfy class I laser safety requirements.
  • The transceivers are compatible with SFP Multi-Source Agreement and SFF-8472 digital diagnostics functions.


Transceiver functional diagram


Absolute Maximum Ratings

Parameter

Symbol

Min

Max

Unit

Supply Voltage

Vcc

-0.5

4.5

V

Storage Temperature

Ts

-40

+85

°C

Operating Humidity

-

5

85

%


Recommended Operating Conditions

Parameter

Symbol

Min

Typical

Max

Unit

Operating Case Temperature

Tc

0


+70

°C

Power Supply Voltage

Vcc

3.135

3.30

3.465

V

Power Supply Current

Icc



550

mA

Data Rate


4.25

14.025


Gbps


Optical and Electrical Characteristics

Parameter

Symbol

Min

Typical

Max

Unit

Notes

Transmitter

Centre Wavelength

λc

1528.77


1563.86

nm


Spectral Width(-20dB)

Δλ



1

nm


Side-Mode Suppression Ratio

SMSR

30

-


dB


Average Output Power

Pout

-1


+3

dBm

1

Extinction Ratio

ER

8.2



dB


Data Input Swing Differential

VIN

180


850

mV

2

Input Differential Impedance

ZIN

90

100

110

Ω


TX Disable

Disable


2.0


Vcc

V


Enable


0


0.8

V


TX Fault

Fault


2.0


Vcc

V


Normal


0


0.8

V


Receiver

Centre Wavelength

λc

1260


1620

nm


Receiver Sensitivity




-14

dBm

3

Receiver Overload


0.5



dBm

3

LOS De-Assert

LOSD



-15

dBm


LOS Assert

LOSA

-28



dBm


LOS Hysteresis


0.5



dB


Data Output Swing Differential

Vout

300


900

mV

4

LOS

High

2.0


Vcc

V


Low



0.8

V


Notes:

1. The optical power is launched into SMF.

2. PECL input, internally AC-coupled and terminated.

3. Measured with a PRBS 231-1 test pattern @14025Mbps, BER ≤1×10-12.

4. Internally AC-coupled.


Timing and Electrical

Parameter

Symbol

Min

Typical

Max

Unit

Tx Disable Negate Time

t_on



2

ms

Tx Disable Assert Time

t_off



100

µs

Time To Initialize, including Reset of Tx Fault

t_init



300

ms

Tx Fault Assert Time

t_fault



100

µs

Tx Disable To Reset

t_reset

10



µs

LOS Assert Time

t_loss_on



100

µs

LOS De-assert Time

t_loss_off



100

µs

Serial ID Clock Rate

f_serial_clock


100

400

KHz

MOD_DEF (0:2)-High

VH

2


Vcc

V

MOD_DEF (0:2)-Low

VL



0.8

V


Diagnostics

Parameter

Range

Unit

Accuracy

Calibration

Temperature

 0 to +70

°C

±3°C

Internal

Voltage

3.0 to 3.6

V

±3%

Internal

Bias Current

0 to 100

mA

±10%

Internal

TX Power

-1 to +3

dBm

±3dB

Internal

RX Power

-16 to -1

dBm

±3dB

Internal


Ordering information

Part Number

Product Description

RSPD-16GD20-C17

SFP+ C17 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C18

SFP+ C18 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C19

SFP+ C19 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C20

SFP+ C20 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C21

SFP+ C21 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C22

SFP+ C22 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C23

SFP+ C23 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C24

SFP+ C24 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C25

SFP+ C25 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C26

SFP+ C26 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C27

SFP+ C27 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C28

SFP+ C28 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C29

SFP+ C29 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C30

SFP+ C30 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C31

SFP+ C31 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C32

SFP+ C32 DWDM, 14.025Gbps, LC, 20km, 0°C~+70C, with DDM

RSPD-16GD20-C33

SFP+ C33 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C34

SFP+ C34 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C35

SFP+ C35 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C36

SFP+ C36 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C37

SFP+ C37 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C38

SFP+ C38 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C39

SFP+ C39 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C40

SFP+ C40 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C41

SFP+ C41 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C42

SFP+ C42 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C43

SFP+ C43 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C44

SFP+ C44 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C45

SFP+ C45 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C46

SFP+ C46 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C47

SFP+ C47 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C48

SFP+ C48 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C49

SFP+ C49 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C50

SFP+ C50 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C51

SFP+ C51 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C52

SFP+ C52 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C53

SFP+ C53 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C54

SFP+ C54 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C55

SFP+ C55 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C56

SFP+ C56 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C57

SFP+ C57 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C58

SFP+ C58 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C59

SFP+ C59 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C60

SFP+ C60 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM

RSPD-16GD20-C61

SFP+ C61 DWDM,14.025Gbps, LC, 20km, 0°C~+70°C, with DDM





想知道这个产品吗?

发送 信息
留言

如果您对我们的产品感兴趣并想了解更多详细信息,请在此处留言,我们将尽快答复您。

相关产品
25G SFP28 Transceiver 25G SFP28 MWDM Optical Transceiver
25G SFP28 MWDM optical transceiver module, support 25Gb/s and up to 10 km transmission, it works in high-speed IDC connection solutions, 5G network front-haul solution, and so on.
偏振控制器 三叶偏振控制器
Low insertion loss Wide wavelength range Easy disassemble,self-replacement,winding fiber
工业级交换机 6电POE千兆工业级交换机 FW304GPS-2G
6*10/100/1000M自适应RJ45端口 FW304GPS-2G 是一款准工业全千兆管理型POE交换机,全端口支持6KV防雷保护,支持电源过温保护、过压保护,浪涌电流保护等多种 保护特性。2个10/100/1000M RJ45上联端⼝,支持IEEE 802.3x 全双⼯流控和半双⼯backpressure 流控。符合IEEE802.3af&at标准,单端口最大PoE功率为30W。高可靠性防护等级,适应各种复杂环境,48-56V DC冗余双电源电压输入,支持直流电源双路冗余供电或双路直流/交流冗余供电,满足不同供电环境中的电力所需。
800G OSFP SR8 MM MPO12 Optical Transceiver IB 800G OSFP SR8 MM MPO12 Optical Transceiver IB
Features OSFP Serial Optical Interface 8x100G PAM4 retimed 800GAUI-8 electrical interface Dual MPO-12 APC connector and MPO16 APC connector are provided 8 channel VCSEL arrays and 8 channels PIN photo detector arrays Maximum link length of 60m on OM3 or 100m on OM4 OSFP MSA Compliant Hot Pluggable OSFP form factor Compliant to OSFP Module Specification Rev 5.0 Compliant with CMIS 5.2 Support Protocol Compliant with IEEE 802.3db Compliant to IEEE 802.3ck Low Power Consumption Less than 14W in temperature range of 0 to 70℃ Applications 800GBASE-SR8 800G Ethernet Data center
100G QSFP28 CWDM4 100G QSFP28 CWDM4 2km LC Optical Transceiver
100G QSFP28 CWDM4 optical transceiver module, support 100Gb/s and up to 2 km transmission on SM fiber, it works in high-speed IDC connection solutions, and so on.
双通道10KHz单元探测器 PDA1000-2 双通道10KHz单元探测器
本系列探测器与Thorlabs、Newport公司的单元探测器使用方法基本一致,电源接口完全相同。在不需要监控(Monitor)输出(Thorlabs和Newport公司部分产品具有),并且带宽相同的情况下可以直接替换,并且各方面性能不差于Thorlabs、Newport同类产品。除已有指标的探测器,还提供定制化服务,可以根据客户需要,调整探测器各项指标(例如供电电压、增益、带宽等)以满足客户需求。
40G QSFP ZR4 40G QSFP+ ZR4 80Km 1310nm LC Optical Transceiver
Features 4 lanes MUX/DEMUX design Integrated LAN WDM TOSA / ROSA Up to 11.2Gbps per channel bandwidth Aggregate bandwidth of > 40Gbps Duplex LC connector Compliant with 40G Ethernet IEEE802.3ba and 40GBASE-ZR4 QSFP MSA compliant APD photo-detector Up to 80 km transmission Compliant with QDR/DDR Infiniband data rates Single +3.3V power supply operating Built-in digital diagnostic functions Temperature range 0°C to 70°C Applications Rack to rack Data centers Switches and Routers Metro networks Switches and Routers 40G BASE-ZR4
4G/5G 前传无源波分复用器 4G/5G 前传无源波分复用器
为满足数据流量的高速增长需求,运营商需不断地增加基站数量。传统的建站方式需要新建机房、购置设备及相关配套器件、投入人力等,周期长、投资与运维成本高。 为避免传统建站方式带来的缺点,运营商逐渐采用将多个BBU(Base Band Unit,基带处理单元)集中放置的方式。这种建站方式降低了机房租金投入、设备成本投入、人力投入等,使得工期大大缩减、投资运维成本大幅降低。但这种方式对光纤资源需求较大。若光纤资源匮乏或无管道资源,则较难实施。 瑞东光电公司的基站拉远光纤扩容系统,提供了一种既可实现BBU集中放置,又能大大减少光纤需求的建网方案。在光纤扩容系统中,通过在BBU和RRU上使用配套的彩光模块,提供不同波长的业务信号。将承载各个波长业务信号的光纤,分别连接到BBU侧和RRU侧的光纤扩展器。两侧的光纤扩展器将不同波长的信号通过线路侧的一条光纤进行传输,从而节省大量的光纤资源。
留言
留言
如果您对我们的产品感兴趣并想了解更多详细信息,请在此处留言,我们将尽快答复您。

首页

产品

关于

联系