other

2X2B磁光开关

Features

  • Solid-state high speed
  • High Stability, High Reliability
  • Epoxy-free on Optical Path
  • Fail-safe latching


Applications

  • Aerospace equipment
  • Configurable Add/Drop
  • System monitoring
  • Sensing system
  • 产品详细信息

M2x2B Magnet Fiber Optical Switch

 

The M2x2B optical switch is connected to the optical path by connecting or blocking the optical signal. the switch has non-mechanical configurations and activated via an electrical control signal. the switch also has build-in circulator and isolator functions. Products are widely used in aerospace and military equipment.


1x2 Magnet Fiber Optical Switch


Performance Specifications


Parameters

Unit

Specifications

Wavelength Range

nm

1520 ~ 1580

Test Wavelength

nm

1550

Insertion Loss1, 2

dB

≤ 1.2

TDL

dB

≤ 0.30

PDL

dB

≤ 0.20

Return Loss

dB

≥ 50

Crosstalk

dB

Bidirectional ≥ 20

Unidirectional ≥ 40

Repeatability

dB

≤ ±0.01

Switching Time

us

≤ 100

Pulse Duration

us

≥ 200

Durability

Cycles

≥10 Bllions

Switch Type

NA

Latching

Operating Current

mA

≤ 200

Maximum Optical Power

mW

≤ 500

Operating Temperature

-5 ~ +70

Storage Temperature

-40 ~ +85

Dimension

mm

(L)30.0×(W)7.5×(H)7.5 ±0.2

Note:  1 Test at room temperature and SOP.

          2 Excluding connectors, 0.2dB for one pair connectors.


Mechanical Dimensions (Unit:mm)




Electrical Drive


Type

Status

Optical Route

Electric Drive

M2x2B

Pin 1

Pin 2

Bidirectional

P1 —— P3


P2 —— P4

GND

V+

P1 —— P4

V+

GND

Unidirectional

P1 → P3

P2 → P4

P4 → P1

GND

V+

P1 → P4

P4 → P2

P3 → P1

V+

GND


Functional Diagram




Ordering Information

FSW-M2x2B-□-□-□-□-□-□-□


—□

—□

—□

—□

—□

—□

—□

Switch Type

Fiber Type

Voltage

Wavelength

Tube Type

FiberLength

Connector

B:

Bidirectional

U:

Unidirectional

SM:

SM,9/125

X:

Others

2.5:

2.5V

X:

5.0V

1550:

1550nm

X:

Others

250:

250um

900:

900um

X:

Others

05:

0.5m±5cm

10:

1.0m±5cm

X:

Others

OO:None

FC:FC/PC

FA:FC/APC

SC:SC/PC

SA:SC/APC

LC:LC/PC

X:Others





想知道这个产品吗?

发送 信息
留言

如果您对我们的产品感兴趣并想了解更多详细信息,请在此处留言,我们将尽快答复您。

相关产品
1X4磁光开关 1X4磁光开关
Features Solid-state high speed High Stability, High Reliability Epoxy-free on Optical Path Fail-safe latching Applications Aerospace equipment Configurable Add/Drop System monitoring Sensing system
1X1磁光开关 1X1磁光开关
Features Solid-state high speed High Stability, High Reliability Epoxy-free on Optical Path Fail-safe latching Applications Aerospace equipment Configurable Add/Drop System monitoring Sensing system
1X2磁光开关 1X2磁光开关
Features Solid-state high speed High Stability, High Reliability Epoxy-free on Optical Path Fail-safe latching Applications Aerospace equipment Configurable Add/Drop System monitoring Sensing system
2X2磁光开关 2X2磁光开关
Features Solid-state high speed High Stability, High Reliability Epoxy-free on Optical Path Fail-safe latching Applications Aerospace equipment Configurable Add/Drop System monitoring Sensing system
1X8磁光开关 1X8磁光开关
Features Solid-state high speed High Stability, High Reliability Epoxy-free on Optical Path Fail-safe latching Applications Aerospace equipment Configurable Add/Drop System monitoring Sensing system
10G SFP+  Transceiver 10G DWDM SFP+ Optical Transceiver
10G SFP+ optical transceiver module, support 10Gb/s and up to 100 km transmission, including: SFP+ SR, SFP+ LR, SFP+ ER, SFP+ ZR, etc. It works in high-speed IDC connection solutions, 5G network front-haul solution, network switch, PTN, OTN and so on.
4G/5G 前传无源波分复用器 4G/5G 前传无源波分复用器
为满足数据流量的高速增长需求,运营商需不断地增加基站数量。传统的建站方式需要新建机房、购置设备及相关配套器件、投入人力等,周期长、投资与运维成本高。 为避免传统建站方式带来的缺点,运营商逐渐采用将多个BBU(Base Band Unit,基带处理单元)集中放置的方式。这种建站方式降低了机房租金投入、设备成本投入、人力投入等,使得工期大大缩减、投资运维成本大幅降低。但这种方式对光纤资源需求较大。若光纤资源匮乏或无管道资源,则较难实施。 瑞东光电公司的基站拉远光纤扩容系统,提供了一种既可实现BBU集中放置,又能大大减少光纤需求的建网方案。在光纤扩容系统中,通过在BBU和RRU上使用配套的彩光模块,提供不同波长的业务信号。将承载各个波长业务信号的光纤,分别连接到BBU侧和RRU侧的光纤扩展器。两侧的光纤扩展器将不同波长的信号通过线路侧的一条光纤进行传输,从而节省大量的光纤资源。
Dual Fiber 8CH CWDM MUX DEMUX 8路 双纤双向 1470nm~1610nm CWDM 带 监控口 LGX 盒子模块
CWDM MUX DEMUX, Multiplexing up to 8 Channels on Fiber Pair 1% Monitor Port for Signal Analyzing or Troubleshooting Passive, Protocol Transparent for Ethernet, FC, OTN, SONET/SDH, etc. Fully Compatible with All ITU-T 1G/10G/25G CWDM Optics Applied to Metro, Regional CWDM Networks
留言
留言
如果您对我们的产品感兴趣并想了解更多详细信息,请在此处留言,我们将尽快答复您。

首页

产品

关于

联系